Sea Ranch Lakes Building Department

Pineland Engineering prepares permit-ready construction documents for Sea Ranch Lakes, Broward County, Florida projects and coordinates directly with the Sea Ranch Lakes Building Department during plan review — so you get your permit faster.

Quick Answer

Start with the Broward County Uniform Building Permit Application on the Village’s Permit Application page. Check the job address before filing for a condominium. Sea Ranch Club Condominiums are in the neighboring Town of Lauderdale-by-the-Sea.

The Village of Sea Ranch Lakes Building Department handles municipal permits at 1 Gatehouse Road, Sea Ranch Lakes, Florida 33308. Call Village Hall at (954) 943-8862, email the completed application to [email protected] or fax it to (954) 943-5808.

Where Can I Verify the Official Requirements?

Filing the Village form

Download and print the form from the Village permit application page.

The building official decides whether drawings, other attachments and payment can be delivered in person. Call the Gatehouse Road office for permit-counter hours and delivery instructions before making the trip. The Village contact and filing pages were checked November 23, 2026.

Choose the trade at the top of the form. Enter the job address and unit, tax folio, floor area, job value and description of work.

For an addition, describe what will change in the house and identify any separate work at the shoreline. The owner or agent and the contractor’s qualifier have separate signature spaces with notary fields. Keep both pages with the email or fax confirmation. Use the job address and tax folio when asking Village Hall for the application number or review status. For replacement A/C equipment, pair the mechanical application with the County’s current A/C replacement data form.

Sources: [1] Village permit application and filing instructions; [2] Village Hall address and telephone; [3] Download the Village’s uniform building permit form; [4] Lauderdale-by-the-Sea comprehensive plan and Sea Ranch Club annexation; [22] Broward County replacement A/C data form; [24] Broward Board of Rules and Appeals policy on replacement A/C permits

When the project also goes to Broward County

For a new house in Sea Ranch Lakes, Broward reviews the project to determine whether impact fees are due.

Its Development and Environmental Review runs through the County’s ePermits system. Broward directs applicants to present the resulting certificates to the municipal building department before the certificates are 30 days old. Broward review instructions and portal

If the project calls for an asbestos responsibility statement, Broward processes it online.

For a new home elevator, the County’s packet calls for an elevator permit application from a licensed elevator contractor and a set of design plans. For replacement windows, Broward publishes a uniform window and door schedule. Ask Village Hall which openings, product approvals and attachment details the reviewer wants identified on that schedule.

Sources: [5] Broward County development and environmental review and ePermits sign-in; [6] Broward County Air Program and asbestos filing; [7] Broward County elevator application packet; [8] Broward Board of Rules and Appeals countywide forms

Village permit fees and review deadlines

Village Code § 5-3 puts permit charges on schedules adopted by the Village Council.

The Village’s 2023 mechanical fee sheet lists a $125.00 minimum for air conditioning, except for a single window or wall unit replaced for maintenance. It also lists $50.00 for plan review. In November 2024 the Council approved including cost recovery in building department fees. For a central A/C changeout, give Village Hall the equipment scope and job value and request the current itemized charge before sending payment.

For a current review date, give Village Hall the application number and ask when the reviewer received a complete file.

Under Florida Statutes § 553.792, if a local government reviewer handles a mechanical permit for work under $15,000 at an existing single-family house, the deadline for a decision is five business days after receipt of a complete and sufficient application, unless the applicant waives that time in writing. The decision may be approval, approval with conditions or denial. If that reviewer is handling a new single-family house under 7,500 square feet, the statute allows 30 business days from a complete and sufficient filing, with the same waiver provision.

Sources: [9] Village Code § 5-3 on permit fees and cancellations; [10] Village fee schedules published with Resolution 2023-04; [11] Village Council minutes approving building department cost recovery; [12] Florida Statutes § 553.792 on deadlines for permit decisions

Requesting an inspection at the job address

Call Village Hall with the issued permit number, the trade and the stage the contractor wants inspected.

Ask how to book the visit and how the inspector will report the result. If the site cannot be ready for a scheduled inspection or test, § 5-3 calls for at least four working hours’ cancellation notice. Keep the appointment time and the cancellation confirmation with the permit.

The Village form warns owners to record and post a required Notice of Commencement at the site before the first inspection.

Florida Statutes § 713.135 also calls for filing a copy with the issuing authority before that inspection when the direct contract exceeds $5,000. That filing rule has an exception for a direct contract under $15,000 to repair or replace an existing heating or air-conditioning system. Give the Village the contract amount and describe whether the A/C is a stand-alone replacement or part of a larger remodel.

Sources: [2] Village Hall address and telephone; [3] Download the Village’s uniform building permit form; [9] Village Code § 5-3 on permit fees and cancellations; [13] Florida Statutes § 713.135 on the Notice of Commencement

A lakefront addition or a seawall repair

On a residential survey, identify the waterway before laying out the addition.

Village Land Development Code § 5.01.02 sets the rear setback at 15 feet from the rear property line on Intracoastal lots and 25 feet on the interior lakes. For grading, § 5.03.03 calls for elevations at the property boundary to match adjacent land or for features that keep runoff from crossing the boundary. Show how the new footprint and drainage fit on the same survey.

The Village adopted the Broward flood maps effective July 31, 2024, and subsequent revisions.

FEMA lists the same date for Sea Ranch Lakes. Use the Flood Map Service Center address search to identify the parcel’s zone for the Village form. The state directory lists the Village Clerk as floodplain administrator. Bring the map and survey to that office if the base flood elevation field on the application is unclear.

For work on a tidally influenced shoreline, distinguish a repair to the cap from replacement of the barrier.

One test for substantial repair is whether the modification affects more than half the property’s shoreline length. A substantially repaired tidal barrier must extend along the property’s entire shoreline. Show the full shoreline length and the length of the planned repair on the same drawing. The Village prohibits docks on interior-water lots. For an Intracoastal dock, its ordinance calls for Army Corps approval of the plans and written committee approval. Ask Village Hall where to send the dock plans alongside the seawall application.

Sources: [14] Village residential lot, setback and grading provisions; [15] FEMA Community Status Book entry for Sea Ranch Lakes; [16] FEMA Flood Map Service Center address search; [17] Florida floodplain administrator directory; [3] Download the Village’s uniform building permit form; [18] Village dock and seawall provisions; [25] Village flood map adoption ordinance

Permit drawings for a Sea Ranch Lakes home

Pineland Engineering can prepare drawings for a lakefront addition showing the distance from the house to the rear lot line, the proposed floor elevation and the direction of runoff at each boundary.

For replacement openings, Pineland can coordinate opening sizes and attachment details with the product information for Broward’s High-Velocity Hurricane Zone.

For current Village applications, use the Florida Building Code 8th Edition (2023), effective December 31, 2023.

If the design schedule runs into late December, confirm the filing date with Village Hall before finishing the drawings. The 9th Edition (2026) takes effect December 31, 2026.

Sources: [14] Village residential lot, setback and grading provisions; [15] FEMA Community Status Book entry for Sea Ranch Lakes; [19] Florida Building Commission materials defining the hurricane zone; [20] Florida Building Commission effective date for the 8th Edition; [21] Florida Building Commission effective date for the 9th Edition

What Do People Ask About Sea Ranch Lakes Building Department?

What permit forms does a Sea Ranch Lakes homeowner need for a new central A/C unit?

For a replacement, select Mechanical on the Village application and include Broward’s residential A/C replacement data form for each system. The data form asks for the old and new equipment, the condensing unit model and whether the location will change. Ask the installer for the AHRI certificate to go with the equipment data.

Does the Florida small-project permit exemption apply in Sea Ranch Lakes?

Florida Statutes § 553.79 has an exemption for qualifying work under $7,500 at a single-family dwelling. It excludes properties partly or wholly in a flood hazard area and excludes electrical, plumbing, structural, mechanical and gas work. To claim the exemption, the owner or contractor must send the local agency a written request with a contract or other documentation of the scope and value. Check the Village parcel’s flood map before submitting that request.

How large a detached shed can go on a Village residential lot?

Ask the Village how it classifies the proposed shed before ordering it. Section 5.01.01 of the Village Land Development Code prohibits accessory buildings on residential lots. A small footprint alone does not resolve that zoning question.

Which office handles a condo inspection at Sea Ranch Club?

The Town of Lauderdale-by-the-Sea identifies Sea Ranch Club Condominiums in its comprehensive plan. For a milestone inspection at that complex, ask the association for the building’s inspection notice and contact the Town with the address on the notice. For another property with “Sea Ranch” in its name, confirm the municipality using its street address and tax folio. Under Florida Statutes § 553.899, the local enforcement agency sends written notice to the association when it determines a milestone inspection is required.

What elevation should a Sea Ranch Lakes seawall permit show?

For a new or substantially repaired tidal flood barrier, the Village specifies a minimum elevation of five feet NAVD88, the survey reference used in its ordinance. An application submitted before January 1, 2035 may qualify for four feet NAVD88 if the barrier is designed and built to accommodate at least five feet NAVD88 by January 1, 2050. Ask the surveyor to identify that reference on the seawall drawing so the Village can compare elevations.

Ready to Start Your Project?

Pineland Engineering — Designda Inc. — serves residential and commercial clients statewide. PO Box 417, Pineland, FL 33945.