The most stringent building code in the continental United States. Miami-Dade's High-Velocity Hurricane Zone (HVHZ) requirements govern all construction in Miami-Dade and Broward counties — from product approval to structural connections.
Interactive Tools
Florida Building Code Expert
8th Edition current · 9th Edition effective Dec. 31, 2026
Hello! I'm your Florida Building Code Expert.
I can answer questions about the 8th Edition FBC (2023) — currently in force — and the published 9th Edition (effective December 31, 2026). Ask me about wind loads, permits, structural requirements, HVHZ, flood zones, and more.
Common Questions
For site-specific engineering, contact Pineland Engineering · (239) 420-1530
Miami-Dade County Code Chapter 8 — current version Jun 17, 2026 · View on Municode
High-Velocity Hurricane Zone
Construction in Miami-Dade and Broward counties must meet these HVHZ-specific requirements in addition to the standard Florida Building Code. These provisions apply to all new construction, additions, and substantial improvements.
For Risk Category II, the code sets 175 mph in Miami-Dade and 170 mph in Broward.
ASCE 7-22 §26 / FBC §1609All exterior building products — windows, doors, roofing, cladding, skylights — must carry a Miami-Dade Notice of Acceptance (NOA) or Florida Product Approval. No substitutions permitted without re-testing.
FBC §1609.1.2 / MDC §8-5All exterior glazing in HVHZ must be impact-resistant (ASTM E1886/E1996 Large Missile Level D) or protected by approved impact-resistant shutters. Standard tempered glass is not sufficient.
FBC §1609.1.2 / MDC §8-5Continuous load path from roof to foundation required. Roof-to-wall, wall-to-floor, and floor-to-foundation connections must be engineered and verified by special inspection. Uplift straps at every rafter/truss.
FBC §1604.8.2 / ASCE 7-22Products must be tested per Miami-Dade test protocols (TAS 100–203) or equivalent ASTM standards. The Miami-Dade Building Code Compliance Office (BCCO) maintains the approved product database.
MDC Chapter 8 Art. IV / FBC §1609Buildings >3 stories or >50 ft require threshold inspections by a licensed structural engineer or architect throughout construction. Threshold inspector must be on-site during critical structural work.
Fla. Stat. §553.79 / FBC §110.3Product Testing Standards
The Florida Building Code Volume — Test Protocols for High-Velocity Hurricane Zones establishes the TAS (Test Application Standard) series. Products must be tested to these standards to receive Miami-Dade NOA approval.
| Protocol | Title |
|---|---|
| TAS 100 | Test Procedure for Wind and Wind Driven Rain Resistance of Exterior Windows, Curtain Walls and Doors |
| TAS 101 | Test Procedure for Structural Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems |
| TAS 110 | Test Procedure for Exterior Glazing Systems |
| TAS 116 | Test Procedure for Roof Tile Systems |
| TAS 117 | Test Procedure for Roof Tile Adhesive Systems |
| TAS 120 | Test Procedure for Roof Coverings |
| TAS 125 | Test Procedure for Roof Deck Assemblies |
| TAS 200 | Test Procedure for Impact and Cyclic Wind Pressure Loading of Exterior Shutters |
| TAS 201 | Impact Test Procedures (Large Missile) |
| TAS 202 | Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components |
| TAS 203 | Criteria for Testing Products Subject to Cyclic Wind Pressure Loading |
Common Questions
Official Sources
Miami-Dade Building Department
Permits, inspections, and code compliance
Miami-Dade NOA Product Approval Database
Search approved products (NOAs)
Miami-Dade County Code Chapter 8
Official building code ordinances
FBC Test Protocols for HVHZ (TAS)
TAS 100–203 test standards
Florida Building Commission
State code adoption and amendments
Miami-Dade ePlan (Electronic Permits)
Online permit submission portal
Pineland Engineering — A Designda Inc. Company — is licensed to practice architecture and engineering throughout Florida, including Miami-Dade County's High-Velocity Hurricane Zone.